Čista zona sterilizacije

 

Kao što smo već naveli, druga zona sterilizacije je čista zona. Po završetku postupka u kontaminiranoj zoni i nakon završetka rada Steelco washer disinfector uređaja za pranje i dezinfekciju, nastavlja se proces u čistoj zoni. Uređaji Steelco su napravljeni sa dvoja pristupna vrata, savremenog dizajna za bezbedan dalji proces. Instrumenti se u kontaminiranoj zoni potom pakuju u uređaj za pranje, a da bi se proces nastavio, nakon zavšetka rada uređaja za pranje, hlade se u čistoj zoni.

Druga faza sterilizacije je pakovanje, jedan od najvažnijih procesa. Važno je svaki instrument ili tkaninu ( hirurški mantil, čaršaf…. ) na pravilan način upakovati.

Kada se instrumenti ohlade, po protokolu se slažu u CBM žičane korpice u koje se na dno stavlja papirni podmetač, napravljen od celuloze, čija je uloga da apsorbuje višak kondenza,kao i da zaštiti oštre vrhove instrumenata od oštećenja ( prolazak sitnijih instrumenata kroz rešetku). Pored instrumenata se u korpicu takođe stavlja integrator pare klase V kompanije Amcor, kao adekvatna kontrola za sterilizaciju (kontrola samog punjenja). Nakon izvršenih priprema, pakuje se u Sterisheet duo papir, kompanije Sterimed,( u nastavku možete pogledati video sa uputsvom pravilnog pakovanja).

Jako je važno, pre započinjanja procesa sterilizacije, obeležiti pakovanje Printex nalepnicama, kojima označavamo datum izvršenog procesa sterilizacije.Printex nalepnice imaju mogućnost i označavanja roka trajanja sterilisanog materijala, kao i ime osobe koja je pakovala ili odeljenja kojima materijal pripada ( u zavisnosti od toga da li su dvoredne ili troredne- korisnik ima individualnu mogućnost izbora sa Printex-om).  Kao takvo pakovanje je spremno za dalji proces sterilizacije.

 

 

Clean area

 

As indicated previously, the second sterilization zone is the clean area. Upon the completion of the process in the contaminated area and after being treated in the Steelco washer disinfector, the process continues in the clean area. With a modern design for a safe reprocessing, Steelco devices are made with a double door system. In the contaminated area, instruments are placed into the device, and in order for the process to continue, after the machine operation, they are cooled in the clean area.

The second sterilization is packaging, one of the most important processes. It is important for every instrument or cloth to be packed properly.

 

When the instruments have cooled, the objects to be treated are inserted in CBM wire mesh baskets with a paper pad on the bottom, that serves to absorb the excessive condensate, as well as to protect sharp instrument tips from damage ( falling of smaller instruments through the mesh basket). In addition to the instruments, steam integrator class V of the Amcor company is inserted in the basket, for an adequate sterilization control (filling control). After the necessary preparations have been made, the instruments are packed in the Sterisheet duo paper, of the Sterimed company (below you can watch the video with instructions on proper packaging).

It is very important to mark the packaging with Printex lables before starting the sterilization process, which indicates the date of a completed sterilization process. Printex labels contain the expiry date of the sterilized material, as well as the responsible person that packed the instruments or departments owning the material (depending on whether it is has two or three print lines – the user can make a choice with Printex materials).  At this stage, the packaging is ready for further sterilization process.